The EcoFlow RIVER 2 Max accepts 11–50 V and up to 13.0 A on its solar input, and converts at most 220 W. The upper voltage is an absolute limit: open-circuit voltage above it damages the port, and panels make more voltage the colder it gets.

27 of the panels in the table fit one more in series at 25 °C than on a Denver record night. For example two ECO-WORTHY 130W 18BB Flexible Solar Panel (GW-L02AM130W18V-1) panels read 49.0 V on the label and 59.6 V at −31.7 °C: wired "in series like in the video", the string crosses the limit.

Parallel wiring is not free either. Two Rich Solar MEGA 200 (RS-M200) panels in parallel short-circuit at 23.2 A against a 13.0 A input; the station limits the current and roughly 44 % of their peak power goes unused. Charging from empty in full sun takes about 2.8 hours from 200 W of panels and 2.3 hours from 400 W, because the station never converts more than 220 W. Behind a cloud or in winter it takes several days.

Check panels on this station

Which panels you can connect

Series count = input limit ÷ cold Voc, rounded down; "no safe wiring" when the start voltage needs more panels in series than the cold limit allows.
PanelIn series at 25 °CAt −10 °CAt −31.7 °C (Denver record)Safe wiringStrings before current clippingAdapter
BougeRV 400W 16BB N-Type Mono Rigid (ISE240N)400 W, Voc 39.7 V111parallel only1MC4 → XT60
BougeRV Arch 100W N-Type Fiberglass Flexible (ISE214N)100 W, Voc 29.4 V111parallel only3MC4 → XT60
BougeRV Arch 200W N-Type Flexible (ISE230N)200 W, Voc 28.0 V111parallel only1MC4 → XT60
BougeRV Arch Pro 100W N-Type TOPCon Flexible (SP003)100 W, Voc 37.8 V111parallel only4MC4 → XT60
BougeRV Arch Pro 200W N-Type TOPCon Flexible (SP004)200 W, Voc 36.4 V111parallel only1MC4 → XT60
BougeRV Curved 200W Mono Flexible (ISE230)200 W, Voc 20.1 V222up to 2s1MC4 → XT60
BougeRV Fiberglass 100W Curved Mono (ISE214)100 W, Voc 19.8 V222up to 2s2MC4 → XT60
BougeRV ShadePower 200W N-Type Rigid (SP005-BK)200 W, Voc 36.4 V111parallel only1MC4 → XT60
BougeRV Yuma 100W CIGS Flexible with Holes (ISE152)100 W, Voc 30.5 V111parallel only2MC4 → XT60
BougeRV Yuma 200 Watt CIGS Flexible Solar Panel with Tape (ISE138)200 W, Voc 30.4 V111parallel only1MC4 → XT60
BougeRV Yuma 200W CIGS Flexible with Holes (ISE154)200 W, Voc 30.4 V111parallel only1MC4 → XT60
Canadian Solar CS6P-265M265 W, Voc 37.9 V111parallel only1MC4 → XT60
Canadian Solar CS6P-285M285 W, Voc 38.6 V111parallel only1MC4 → XT60
Canadian Solar CS6X-305P305 W, Voc 44.8 V110burns the input even alone in the cold1MC4 → XT60
Canadian Solar CS6X-325P325 W, Voc 45.5 V100burns the input even alone in the cold1MC4 → XT60
Canadian Solar CS6X-330P330 W, Voc 45.6 V100burns the input even alone in the cold1MC4 → XT60
ECO-WORTHY 130W 18BB Flexible Solar Panel (GW-L02AM130W18V-1)130 W, Voc 24.5 V211parallel only2s burns the input in the cold2MC4 → XT60
ECO-WORTHY 195W N-Type 18BB Bifacial Solar Panel (GW-L02M195NTM-1)195 W, Voc 21.2 V221parallel only2s burns the input in the cold1MC4 → XT60
EcoFlow 160W Portable Solar Panel (EF-Fold-P160-04)160 W, Voc 21.3 V222up to 2s1MC4 → XT60
EcoFlow 220W Bifacial Portable Solar Panel (EF-Fold-G220-04)220 W, Voc 21.5 V222up to 2s1MC4 → XT60
EcoFlow 400W Portable Solar Panel400 W, Voc 48.0 V100burns the input even alone in the cold1MC4 → XT60
EcoFlow 60W Portable Solar Panel (EF-Fold-P060-CG)60 W, Voc 25.5 V111parallel only4MC4 → XT60
Go Power! GP-PV-100M 100W Solar Module100 W, Voc 22.6 V211parallel only2s burns the input in the cold2MC4 → XT60
Go Power! GP-PV-200M 200W Solar Module (Overlander)200 W, Voc 24.3 V211parallel only2s burns the input in the cold1MC4 → XT60
Grape Solar GS-410-54MH-M10410 W, Voc 37.5 V111parallel only1MC4 → XT60
Grape Solar GS-STAR-100W100 W, Voc 23.1 V211parallel only2s burns the input in the cold2MC4 → XT60
Grape Solar GS-STAR-200W200 W, Voc 24.4 V211parallel only2s burns the input in the cold1MC4 → XT60
HQST HSP200N-64L 200W 16BB N-Type200 W, Voc 22.4 V221parallel only2s burns the input in the cold1MC4 → XT60
HQST HSP200N-64LT 200W Compact Bifacial N-Type200 W, Voc 22.4 V221parallel only2s burns the input in the cold1MC4 → XT60
HQST Traver Force TSP100D-30 100W 10BB100 W, Voc 20.5 V222up to 2s2MC4 → XT60
Jackery SolarSaga 200W200 W, Voc 22.0 V221parallel only2s burns the input in the cold1MC4 → XT60
Jinko Solar JKM265M-60B265 W, Voc 38.2 V111parallel only1MC4 → XT60
Jinko Solar JKM285M-60285 W, Voc 38.7 V111parallel only1MC4 → XT60
Jinko Solar JKM305M-72305 W, Voc 46.8 V100burns the input even alone in the cold1MC4 → XT60
Jinko Solar JKM325M-72325 W, Voc 46.5 V100burns the input even alone in the cold1MC4 → XT60
Jinko Solar JKM340P-72345 W, Voc 47.5 V100burns the input even alone in the cold1MC4 → XT60
Jinko Solar JKM365M-72365 W, Voc 48.2 V100burns the input even alone in the cold1MC4 → XT60
Newpowa NPA110S-09I 110W 9V Mono110 W, Voc 18.2 V222up to 2s1MC4 → XT60
Newpowa NPA120S-24J 120W 24V Mono120 W, Voc 44.7 V100burns the input even alone in the cold3MC4 → XT60
Newpowa NPA150S-12J 150W 12V Mono150 W, Voc 20.4 V222up to 2s1MC4 → XT60
Newpowa NPA170D-12J 170W 12V Mono170 W, Voc 21.6 V221parallel only2s burns the input in the cold1MC4 → XT60
Newpowa NPA180S-12J 180W 12V Mono180 W, Voc 21.9 V221parallel only2s burns the input in the cold1MC4 → XT60
Newpowa NPA220S-12J 220W 12V Mono220 W, Voc 20.5 V222up to 2s1MC4 → XT60
REC REC285TP2285 W, Voc 38.6 V111parallel only1MC4 → XT60
REC REC300TP2300 W, Voc 39.2 V111parallel only1MC4 → XT60
REC REC325TP2S 72325 W, Voc 45.9 V100burns the input even alone in the cold1MC4 → XT60
REC REC345TP2S 72345 W, Voc 46.5 V100burns the input even alone in the cold1MC4 → XT60
REC REC365TP2SM 72365 W, Voc 47.6 V100burns the input even alone in the cold1MC4 → XT60
REC REC380TP2SM 72380 W, Voc 48.2 V100burns the input even alone in the cold1MC4 → XT60
Renogy RNG-175D175 W, Voc 21.6 V221parallel only2s burns the input in the cold1MC4 → XT60
Renogy RNG-50DB-H50 W, Voc 22.6 V211parallel only2s burns the input in the cold4MC4 → XT60
Renogy RSP100DC 100W 16BB N-Type100 W, Voc 22.8 V221parallel only2s burns the input in the cold2MC4 → XT60
Renogy RSP100DCT 100W N-Type Bifacial100 W, Voc 28.5 V111parallel only2MC4 → XT60
Renogy RSP175DC 175W N-Type175 W, Voc 24.5 V211parallel only2s burns the input in the cold1MC4 → XT60
Renogy RSP200D-G3 200W Monocrystalline200 W, Voc 23.0 V211parallel only2s burns the input in the cold1MC4 → XT60
Renogy RSP200DB-72-G1 200W Flexible200 W, Voc 23.9 V211parallel only2s burns the input in the cold1MC4 → XT60
Renogy RSP200DC 200W N-Type200 W, Voc 37.4 V111parallel only1MC4 → XT60
Renogy RSP320DT-BKx2-G2 320W N-Type Bifacial320 W, Voc 35.0 V111parallel only1MC4 → XT60
Renogy RSP400DCT-108x2 400W N-Type Bifacial400 W, Voc 39.4 V111parallel only1MC4 → XT60
Renogy RSP450D-120450 W, Voc 41.3 V111parallel only1MC4 → XT60
Rich Solar MEGA 100 FLEX (RS-F100B)100 W, Voc 20.4 V222up to 2s2MC4 → XT60
Rich Solar MEGA 200 PRO FLEX (RS-F200PB)200 W, Voc 40.8 V111parallel only2MC4 → XT60
Rich Solar MEGA 100 (RS-M100)100 W, Voc 22.8 V211parallel only2s burns the input in the cold2MC4 → XT60
Rich Solar MEGA 100 ONYX (RS-M100B)100 W, Voc 22.8 V211parallel only2s burns the input in the cold2MC4 → XT60
Rich Solar MEGA 100 SLIM (RS-M100SL25)100 W, Voc 23.6 V211parallel only2s burns the input in the cold2MC4 → XT60
Rich Solar MEGA 100 SLIM ONYX (RS-M100SLB)100 W, Voc 23.6 V211parallel only2s burns the input in the cold2MC4 → XT60
Rich Solar MEGA 130 SLIM (RS-M130SL)130 W, Voc 23.6 V211parallel only2s burns the input in the cold1MC4 → XT60
Rich Solar MEGA 130 SLIM ONYX (RS-M130SLB)130 W, Voc 23.6 V211parallel only2s burns the input in the cold1MC4 → XT60
Rich Solar MEGA 150 (RS-M150)150 W, Voc 21.8 V221parallel only2s burns the input in the cold1MC4 → XT60
Rich Solar MEGA 175 PRO (RS-M175P)175 W, Voc 36.4 V111parallel only2MC4 → XT60
Rich Solar MEGA 200 (RS-M200)200 W, Voc 21.8 V221parallel only2s burns the input in the cold1MC4 → XT60
Rich Solar MEGA 200 ONYX (RS-M200B)200 W, Voc 21.8 V221parallel only2s burns the input in the cold1MC4 → XT60
Rich Solar MEGA 200 PRO (RS-M200P)200 W, Voc 43.5 V110burns the input even alone in the cold2MC4 → XT60
Rich Solar MEGA 250 PRO (RS-M250P)250 W, Voc 44.7 V110burns the input even alone in the cold1MC4 → XT60
Rich Solar MEGA 400 (RS-M400)400 W, Voc 37.1 V111parallel only1MC4 → XT60
Rich Solar MEGA 50 50 Watt 12V Solar Panel (RS-M50)50 W, Voc 20.8 V222up to 2s4MC4 → XT60
Rich Solar MEGA 50 ONYX (RS-M50B)50 W, Voc 22.8 V211parallel only2s burns the input in the cold4MC4 → XT60
Trina Solar TSM-265PA0505265 W, Voc 38.3 V111parallel only1MC4 → XT60
Trina Solar TSM-285DD05A(II)285 W, Voc 39.3 V111parallel only1MC4 → XT60
Trina Solar TSM-305PA14305 W, Voc 45.2 V100burns the input even alone in the cold1MC4 → XT60
Trina Solar TSM-325DD14A325 W, Voc 46.0 V100burns the input even alone in the cold1MC4 → XT60
Trina Solar TSM-345DD14A(II)345 W, Voc 46.8 V100burns the input even alone in the cold1MC4 → XT60
Trina Solar TSM-360DD14A(II)360 W, Voc 47.2 V100burns the input even alone in the cold1MC4 → XT60

What it runs, and for how long

Hours = usable Wh ÷ (watts × duty cycle ÷ 0.88 for AC). Station inverter efficiency is not published; 0.88 is the engine default.
ApplianceRatedHours from full
LED chart table reading lampHella Marine Flexi Spot 2JA 343 7202 W256.0 h
LED swivel reading lightScandvik 413662 W256.0 h
12 V LED RV porch lightKohree HP4233 W189.6 h
LED surface mount strip lampHella Marine Surface Mount Strip Lamp 2JA 958 1213 W170.7 h
LED brass reading lightScandvik 19052P3 W165.2 h
Compact LED utility lightLumitec Mini Rail2 1012414 W128.0 h
12 V fanCaframo Sirocco II4 W121.9 h
Electric macerating marine/RV toilet, 12 VDometic MasterFlush 7160, ORBIT base240 W106.7 h
Compressor fridge/freezer, dual zoneDometic CFX3 75DZ59 W58.2 h
12 V COB LED strip light, 40 inDream Lighting 0043615-COB10 W53.3 h

Stations of the same size

Prices are not tracked yet, so the comparison is by capacity and solar input.
StationUsableSolar input
BLUETTI AC50B448 Wh28 V, 200 W
BLUETTI EB3A269 Wh28 V, 200 W
BLUETTI EB55537 Wh28 V, 200 W

Source: manufacturer specifications

Where to buy

As an Amazon Associate and through direct retailer programs, this site earns from qualifying purchases — see how.

No direct manufacturer program is joined yet (§13.3); prices marked with an image and a dollar figure are a specific listing checked via the Amazon Creators API, the rest are plain searches.

How this page was computed

A wiring is safe when open-circuit voltage at the temperature stays at or below the input maximum and stays at or above the start voltage. Current above the input limit is clipped, not dangerous.

The formulas are the same open engine the checker runs; the methodology page lists every constant.

These results are for reference. Wiring must be installed by a qualified electrician. Mobile installations follow ABYC E-11; stationary ones NEC 690/706.