Every figure below starts from the datasheet: 22.40 V, 19.20 V, Isc 11.04 A at 25 °C, and a Voc temperature coefficient of −0.28 % per °C. That coefficient means the open-circuit voltage climbs 15.4 % by −30 °C, to 25.8 V per panel.
Read the cold column. On a 25 V controller this panel fits 1 in series at 25 °C but only none at −30 °C, so a string wired from the label number fails the first hard frost.
Where you install it changes the answer on the same 100 V controller: 4 in series in Honolulu, Key West, Fort Lauderdale, Miami and 136 more; 3 in series in Alpine, Marfa, Albuquerque, Greensboro and 174 more, using each city's design low.
For wiring, one string carries 11.04 A of short-circuit current, so the cable and any string fuse are sized for 17.2 A (Isc × 1.56, NEC 690.8). Because the drop is measured against string voltage, not 12 V, the cable stays thin: 2 in series over 5 m need 12 (1.4 % drop at 38.4 V) and 4 in series over 10 m need 12 AWG (1.4 % drop at 76.8 V).
Most panels in series per controller
| Controller input limit | At 25 °C | At −10 °C | At −30 °C |
|---|---|---|---|
| 25 VRenogy Wanderer Li 30A PWM (RNG-CTRL-WND30-LI) | 1 | 1 | none |
| 28 VVictron Energy BlueSolar PWM Charge Controller LCD&USB 12/24-30 | 1 | 1 | 1 |
| 50 VRenogy Adventurer Li 30A PWM (RNG-CTRL-ADV30-LI), Renogy Wanderer 10A PWM (RNG-CTRL-WND10) +1 | 2 | 2 | 1 |
| 60 VMorningstar SunSaver MPPT (SS-MPPT-15L) | 2 | 2 | 2 |
| 75 VVictron Energy SmartSolar MPPT 75/15 | 3 | 3 | 2 |
| 100 VBougeRV Sunflow 40A MPPT Solar Charge Controller (ISE218), BougeRV Sunflow 60A MPPT Solar Charge Controller (ISE219) +15 | 4 | 4 | 3 |
| 120 VMorningstar ProStar MPPT 25 (PS-MPPT-25), Morningstar ProStar MPPT 40 (PS-MPPT-40) | 5 | 4 | 4 |
| 140 VRenogy Rover 100A MPPT (RNG-CTRL-RVR100), Renogy Rover 60A MPPT (RNG-CTRL-RVR60) | 6 | 5 | 5 |
| 145 VHQST 60A MPPT Solar Charge Controller with Bluetooth (HCC60HTR-FC), Rich Solar 60 Amp MPPT (RS-MPPT60) | 6 | 5 | 5 |
| 150 VEPEVER Tracer3215BN, EPEVER Tracer4215BN +13 | 6 | 6 | 5 |
| 200 VEPEVER Tracer 10420AN, MidNite Solar Classic 200 | 8 | 8 | 7 |
| 250 VMidNite Solar Classic 250, Victron Energy SmartSolar MPPT 250/60 | 11 | 10 | 9 |
Datasheet
| Field | Value |
|---|---|
| Power | 200 W |
| Voc / Vmp | 22.40 V / 19.20 V |
| Isc / Imp | 11.04 A / 10.50 A |
| Voc coefficient | −0.28 %/°C |
| Size | 1,175 × 765 mm, 0.90 m² |
| Type | rigid, mono, MC4 |
Source: manufacturer datasheet
Similar panels
- BougeRV ShadePower 200W N-Type Rigid (SP005-BK) 200 W, Voc 36.4 V
- Go Power! GP-PV-200M 200W Solar Module (Overlander) 200 W, Voc 24.3 V
- HQST HSP200N-64LT 200W Compact Bifacial N-Type 200 W, Voc 22.4 V
Where to buy
As an Amazon Associate and through direct retailer programs, this site earns from qualifying purchases — see how.
HQST HSP200N-64L 200W 16BB N-Type 119.99 USD- BougeRV ShadePower 200W N-Type Rigid (SP005-BK)
Go Power! GP-PV-200M 200W Solar Module (Overlander) 485.48 USD
No direct manufacturer program is joined yet (§13.3); prices marked with an image and a dollar figure are a specific listing checked via the Amazon Creators API, the rest are plain searches.
How this page was computed
Series count = controller limit ÷ (Voc × (1 + coefficient × (T − 25))), rounded down. PV cable: ampacity from ABYC E-11 against Isc × 1.56, voltage drop against string Vmp with a 2 % limit.
- Manufacturer datasheet or CEC PV module list verified 2026-09-15
- Design lows: NOAA NCEI GHCN-Daily, 1991–2020 318 locations
The formulas are the same open engine the checker runs; the methodology page lists every constant.