What limits this battery is its rather than its 270 Ah: 300 A continuous and 500 A for 30 s. Behind a 12 V inverter that is at most 2,731 W of steady load before the 15 % margin is gone, because the inverter draws its power divided by 12.6 V and by an efficiency we cap at 85 %.

A 2000 W inverter pulls 186.7 A, so it needs 1 of these in parallel; one 3.46 kWh bank of them stores 3,456 Wh usable at 100 % depth of discharge.

On its own it holds a weekend van (400 Wh a day) load for 8.6 days and the year-round van profile (895 Wh) for 3.9 days, with no sun at all. Its 135 A charge limit also caps the solar side: one battery accepts about 1,940 W of panels behind an at 14.4 V charging voltage, so a bigger array needs a second battery or a controller set to limit current. It has a built-in heater, so the lithium-freeze check passes where a plain LiFePO4 battery fails.

Add to a build

Largest inverter it carries

Max inverter = BMS continuous × 0.85 × 12.6 V × 0.85 efficiency. Surge checked against the BMS peak where both are published.
Batteries in parallelBMS continuousMax inverterInverters in the catalog that fit
1 ×300 A2,731 WBougeRV 2000W 12V Pure Sine Wave Inverter with Bluetooth (2,000 W), HQST 2000W 12V Pure Sine Wave Inverter (HI1220PG2-BR-G1-US) (2,000 W)
2 ×600 A5,462 WAIMS Power PWRINV5K24012W (5,000 W), Victron Energy MultiPlus-II 12/5000/220-50 230V (4,000 W)
3 ×900 A8,193 WAIMS Power PWRINV5K24012W (5,000 W), Victron Energy MultiPlus-II 12/5000/220-50 230V (4,000 W)

Datasheet

FieldValue
Capacity270 Ah at 12.8 V
BMS continuous / peak300 A / 500 A, 30 s
Max charge135 A
Charge below−3.9 °C, heated
Depth of discharge100 %, 3,000 cycles

Source: manufacturer documentation

Similar batteries

Where to buy

As an Amazon Associate and through direct retailer programs, this site earns from qualifying purchases — see how.

No direct manufacturer program is joined yet (§13.3); prices marked with an image and a dollar figure are a specific listing checked via the Amazon Creators API, the rest are plain searches.

How this page was computed

Inverter DC draw = watts ÷ (12.6 V under load × 0.85). A pairing passes when that draw stays at or below 85 % of the combined BMS continuous rating and the surge draw stays under the BMS peak.

The formulas are the same open engine the checker runs; the methodology page lists every constant.

These results are for reference. Wiring must be installed by a qualified electrician. Mobile installations follow ABYC E-11; stationary ones NEC 690/706.